Wire ampacity calculator enter the information below to calculate the maximum allowable ampacity for current carrying conductors.
4 0 awg cable ampacity.
The cross sectional area of each gauge is an important factor for determining its.
For example 3 0 awg copper has an ampacity of 200 amps at 75 while 3 0 awg aluminum has an ampacity of 155 amps at 75.
Aluminum conductors copper clad conductors.
Or 15 amperes for 12 awg and 25 amoeres for 10 awg aluminum after any correction.
Dimensions of the wires are given in astm standard b 258.
Ampacities of insulated conductors from nec table 310 16 not more than three conductors in raceway or cable or earth directly buried based on ambient temperature of 30 c 86 f size.
Allowable ampacities of insulated copper conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient temperature of 30 c 86 f.
The following calculator calculates the voltage drop and voltage at the end of the wire for american wire gauge from 4 0 awg to 30 awg aluminum or copper wire.
60 c 140 f 75 c.
Battery cable is used to power your electrical system and is sized according to the american wire gauge or awg for short specification for electrically conductive cables.
Usually a general purpose house circuit is designed for 20.
Factors tor ambient temperature and number of conductors have been applied.
Our battery cable is american made and comes in gauge awg sizes of 6 4 2 1 1 0 2 0 3 0 and 4 0 with 6 gauge being the smallest and 4 0 gauge being the largest.
The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor.
It just calculates the voltage drop consult the above table for rules of thumb or your local or national electrical code or your electrician to decide what is legal.
Each has a different ampacity for a specified gauge size and these ampacities are found in nec table 310 15 b 16 for the calculations in this app.
Current is measured in amperes or amps.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating.
14 awg 12 awg 10 awg 8 awg 6 awg 4 awg 3 awg 2 awg 1 awg 1 0 awg 2 0 awg 3 0 awg 4 0 awg 250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 700 kcmil 750 kcmil 800 kcmil 900 kcmil.
Wire size awg or kcmil.
Allowable ampacities of conductors in free air.
Wire cable type.