Stratawall shaft wall cinema wall and securitywall.
2 hr fire rated wall detail.
5 8 15 9 mm toughrock fireguard c gypsum board or 5 8 densarmor plus fireguard c gypsum panels applied perpendicular to resilient channels 24 o c.
50 8 mm light gauge steel h studs that secure two layers of 1 in.
For occupancies such as stores apartments of fices and other commercial and industrial uses build ing codes commonly require floor ceiling and wall assemblies to be fire resistance rated in accordance with standard fire tests.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Typical floor ceiling juncture 1.
610 mm with 1 25 4 mm type s drywall screws 12 305 mm o c.
According to the book commercial drafting and detailing a typical one hour fire rated wall consists of 2x4 studs spaced 16 inches from the center of one stud to the center of the next covered by 5 8 inch type x gypsum board.
2 hour area separation wall system the 2 hour area separation wall system is a 2 hour fire wall consisting of 2 in.
25 4 mm shaftliner panels friction fit between studs and a minimum 3 4 in.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm.
Ul design u411 v438.
Type x gypsum board is wallboard to which non combustible fibers have been added.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
Widely recognized by the gold color densglass fiberglass mat gypsum sheathing has an exemplary track record that spans more than 30 years.
Ss 210 2 hour partition to concrete slab.
Put two sheets together on one side or use one sheet on each side of a wall.
19 1 mm air space on each side.
Head of wall firestop system firestop sealant.
For class 2 to 9 buildings including multi residential and commercial buildings gyprock fire performance solutions include.
Fire rated wood frame wall and floor ceiling assemblies.
Each system can be customised to provide the exact level of fire performance required and a range of acoustic and thermal performance to meet each specific.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
These listings are short summaries to serve as a.
It is a preferred substrate under brick stone stucco siding and eifs due to its ability to protect a structure against incidental moisture during and after construction.